E.CT S TURBIDITY

EC.T S TURBIDITY

SENSOR is used for OPTICAL TURBIDITY IN PURE AND PROCESS WATER up to 4000 NTU (SUSPENDED SOLIDS)
Only for NEXUS.TBSERIES
Applications: WASTEWATER, PRIMARY WATER, INDUSTRIAL WATER, RECIRCULATING WATER
Reliable concentration measurement using OPTICAL MEASURING PROCESS (880 mm)
90° SCATTERING LIGHT METHOD
NO MECHANICALLY MOVING PARTS
MEASURED VALUE PRE-PROCESSING IN SENSOR resulting in low signal transmission sensitivity

TECHNICAL FEATURES

RANGE 0÷4/0÷40/0÷400/0÷4000 NTU
THREAD 1” GAS
ACCURACY ±3% F.S
REPEATABILITY 98%
CALIBRATION points
TEMPERATURE 0÷60 °C
MAX PRESSURE 4 bar
MATERIAL SS316, Special Optical Glass or Viton
PROTECTION DEGREE IP68 (included cable)
CABLE LENGHT 10 m
OUTPUT RS485
DIMENSIONS Ø 42x230 mm